Product Center

Refine to perfection, stand firm on reliability

UCMP Controller

%{tishi_zhanwei}%

Product Type

Product Image

Product Model

Dimensions

Rated Input

(m/s)

Main Function Description

Learn More

JSQ24-150D

390×190×67

AC220V±10%

1. Power conversion. 2. After the external power grid is cut off, the DC48V backup power supply provides power to maintain the clamper without triggering. 3. When UCM or overspeed occurs, the UCMP switch or overspeed switch signal disconnection time ≥150ms triggers the clamper.

JSQ24-150

390×190×67

AC220V±10%

1. Power conversion. 2. The clamping device remains inactive for ≥10s after external power failure. 3. When UCM or overspeed occurs, the UCMP switch or overspeed switch signal disconnection time ≥50ms triggers the clamping device.

UCMP-C

330×230×105

AC220V±10%

1. Receives gate area, door lock, overspeed, and elevator running signals; detects UCM and sends control signals to the clamping device. 2. Gate switch, power supply, circuit self-check, and external power grid power failure trigger the clamping device with a delay. 3. Non-UCM and overspeed cause the clamping device to be triggered; after being triggered by external power grid power failure, it automatically resets upon power-on. After a UCM or overspeed fault occurs, the fault must be eliminated before resetting (manual reset button or automatic reset upon power-on). 4. Dual-channel input self-check for redundant safety protection. 5. Used with clamping devices and other protective devices; it is a relatively independent overall solution. 6. Reserved wear detection or other device backup interfaces for easy function expansion.

< 1 >